AMO-Tools-Suite
v.0.9.0
Set of tools for calculating energy efficiency in industrial equipment
|
Contains some of the Fan related classes. More...
#include <CompressibilityFactor.h>
Public Member Functions | |
CompressibilityFactor (const double moverShaftPower, const double inletPressure, const double outletPressure, const double barometricPressure, const double flowRate, const double specificHeatRatio) | |
double | calculate () |
CompressibilityFactor (const double moverShaftPower, const double inletPressure, const double outletPressure, const double barometricPressure, const double flowRate, const double specificHeatRatio) | |
double | calculate () |
CompressibilityFactor (const double moverShaftPower, const double inletPressure, const double outletPressure, const double barometricPressure, const double flowRate, const double specificHeatRatio) | |
double | calculate () |
Contains some of the Fan related classes.
Compressability Factor calculator class Calculates the compressability factor
Compressability Factor calculator class Calculates the compressability factor
Compressability Factor calculator class Calculates the compressability factor
Definition at line 20 of file CompressibilityFactor.h.
|
inline |
Constructor
moverShaftPower | double, in horsepower (hp) |
inletPressure | double, in inches of water column, gauge |
outletPressure | double, in inches of water column, gauge |
barometricPressure | double, in Hg |
flowRate | double, in cfm |
specificHeatRatio | double, unitless |
Definition at line 32 of file CompressibilityFactor.h.
|
inline |
Constructor
moverShaftPower | double, in horsepower (hp) |
inletPressure | double, in inches of water column, gauge |
outletPressure | double, in inches of water column, gauge |
barometricPressure | double, in Hg |
flowRate | double, in cfm |
specificHeatRatio | double, unitless |
Definition at line 32 of file CompressibilityFactor.h.
|
inline |
Constructor
moverShaftPower | double, in horsepower (hp) |
inletPressure | double, in inches of water column, gauge |
outletPressure | double, in inches of water column, gauge |
barometricPressure | double, in Hg |
flowRate | double, in cfm |
specificHeatRatio | double, unitless |
Definition at line 32 of file CompressibilityFactor.h.
|
inline |
inletPressure | double, in inches of water column, gauge |
barometricPressure | double, in Hg |
outletPressure | double, in inches of water column, gauge |
moverShaftPower | double, in horsepower |
flowRate | double, in cfm |
specificHeatRatio | double, unitless |
Definition at line 45 of file CompressibilityFactor.h.
|
inline |
inletPressure | double, in inches of water column, gauge |
barometricPressure | double, in Hg |
outletPressure | double, in inches of water column, gauge |
moverShaftPower | double, in horsepower |
flowRate | double, in cfm |
specificHeatRatio | double, unitless |
Definition at line 45 of file CompressibilityFactor.h.
|
inline |
inletPressure | double, in inches of water column, gauge |
barometricPressure | double, in Hg |
outletPressure | double, in inches of water column, gauge |
moverShaftPower | double, in horsepower |
flowRate | double, in cfm |
specificHeatRatio | double, unitless |
Definition at line 45 of file CompressibilityFactor.h.