AMO-Tools-Suite
v.0.9.0
Set of tools for calculating energy efficiency in industrial equipment
|
#include <GasFlueGasMaterial.h>
Public Member Functions | |
GasFlueGasMaterial (const double flueGasTemperature, const double excessAirPercentage, const double combustionAirTemperature, GasCompositions compositions, const double fuelTemperature) | |
double | getHeatLoss () |
GasFlueGasMaterial (const double flueGasTemperature, const double excessAirPercentage, const double combustionAirTemperature, GasCompositions compositions, const double fuelTemperature) | |
double | getHeatLoss () |
GasFlueGasMaterial (const double flueGasTemperature, const double excessAirPercentage, const double combustionAirTemperature, GasCompositions compositions, const double fuelTemperature) | |
double | getHeatLoss () |
Gas Flue Gas Material class Contains all of the properties of a gas flue gas material. Used to calculate the heat loss caused by carrying the products of combustion out of the system through the flue.
Definition at line 246 of file GasFlueGasMaterial.h.
|
inline |
Constructor for the flue gas losses with all inputs specified
flueGasTemperature | double, Furnace Flue Gas Temperature in °F |
excessAirPercentage | double, Percent Excess Air, expressed in normal percentage (i.e. 9% as 9 instead of 0.09) |
combustionAirTemperature | double, Combustion Air Temperature in °F |
compositions | - GasComposition, User defined gas compositions |
fuelTemperature | double - temperature of fuel |
Definition at line 257 of file GasFlueGasMaterial.h.
|
inline |
Constructor for the flue gas losses with all inputs specified
flueGasTemperature | double, Furnace Flue Gas Temperature in °F |
excessAirPercentage | double, Percent Excess Air, expressed in normal percentage (i.e. 9% as 9 instead of 0.09) |
combustionAirTemperature | double, Combustion Air Temperature in °F |
compositions | - GasComposition, User defined gas compositions |
fuelTemperature | double - temperature of fuel |
Definition at line 257 of file GasFlueGasMaterial.h.
|
inline |
Constructor for the flue gas losses with all inputs specified
flueGasTemperature | double, Furnace Flue Gas Temperature in °F |
excessAirPercentage | double, Percent Excess Air, expressed in normal percentage (i.e. 9% as 9 instead of 0.09) |
combustionAirTemperature | double, Combustion Air Temperature in °F |
compositions | - GasComposition, User defined gas compositions |
fuelTemperature | double - temperature of fuel |
Definition at line 257 of file GasFlueGasMaterial.h.
double GasFlueGasMaterial::getHeatLoss | ( | ) |
Gets the heat loss
Definition at line 179 of file GasFlueGasMaterial.cpp.
double GasFlueGasMaterial::getHeatLoss | ( | ) |
Gets the heat loss
double GasFlueGasMaterial::getHeatLoss | ( | ) |
Gets the heat loss